Technical parameter,weight and installing dimensions (S9 SERIES)
|
Rated cap
acity (kVA) |
Voltage comb
ination (kV) |
Conn
ection type |
Impedance volt
|
Loss
(kW) |
No-load cu
rent (%) |
Weight(T) |
Gauge vertical
/horizonta
l (mm) |
No-load |
load |
machine weight |
oil weight |
overall weight |
630 |
11 , 10.5 , 10 , 6.3 , 6, 3 , 3.15, 6.3 |
Y dll |
4.5 |
1.06 |
6.20 |
0.90 |
1.650 |
0.451 |
2.610 |
750/600 |
800 |
5.5 |
1.23 |
7.50 |
0.80 |
1.900 |
0.517 |
3.105 |
850/660 |
1000 |
1.50 |
10.30 |
0.70 |
2.175 |
0.600 |
3.660 |
850/820 |
1250 |
1.72 |
12.80 |
0.60 |
2.480 |
0.700 |
4.070 |
850/820 |
1600 |
2.20 |
14.50 |
0.60 |
2.680 |
0.780 |
4.460 |
900/820 |
2000 |
2.65 |
17.10 |
0.60 |
3.100 |
0.890 |
5.270 |
900/820 |
2500 |
3.00 |
20.00 |
0.60 |
3.820 |
0.960 |
6.370 |
1070/1070 |
3150 |
3.52 |
23.70 |
0.50 |
4.440 |
1.175 |
7.800 |
1071/1070 |
4000 |
4.32 |
28.10 |
0.50 |
5.300 |
1.580 |
9.350 |
1071/1070 |
5000 |
5.15 |
32.70 |
0.50 |
6.250 |
1.760 |
11.080 |
1071/1070 |
6300 |
6.12 |
36.90 |
0.50 |
7.320 |
1.930 |
13.150 |
1071/1070 |
Note:1.it can supply voltage regulating range of ±5% or ±2×2.5% for high voltage of non-exciting regulation transformer according to the requirements. |
|
Thchnical parameter,weight and installing dimensions(S9 SERIES)
|
Rated capa
city (kVA) |
Voltage combi
nation (kV) |
Conne
ction type |
Impedance voltage
(%) |
Los
(kW) |
No-load curr
ent (%) |
Weight
(T) |
Gauge vertical/
horizontal (mm) |
No-load |
load |
machine weight |
oil weight |
overall weight |
200 |
11 , 10.5 , 10 , 6.3 , 6, 0.4 |
Yyno & D Ynll |
4 |
0.43 |
2.50 |
1.2 |
0.780 |
0.88 |
0.260 |
550/550 |
250 |
0.50 |
2.90 |
1.1 |
0.970 |
0.97 |
0.305 |
650/550 |
315 |
0.59 |
3.45 |
1.0 |
1.020 |
1.12 |
0.350 |
650/550 |
400 |
0.71 |
4.15 |
0.9 |
1.40 |
1.28 |
0.430 |
750/550 |
500 |
0.85 |
4.82 |
0.9 |
1.650 |
1.45 |
0.450 |
750/660 |
630 |
1.06 |
5.86 |
0.8 |
1.600 |
1.70 |
0.530 |
750/660 |
800 |
4.5 |
1.23 |
7.20 |
0.7 |
1.850 |
1.95 |
0.600 |
850/660 |
1000 |
1.50 |
9.80 |
0.6 |
2.180 |
2.218 |
0.680 |
850/820 |
1250 |
1.72 |
12.20 |
0.6 |
2.320 |
2.42 |
0.770 |
850/820 |
1600 |
2.20 |
13.80 |
0.6 |
2.740 |
2.87 |
0.875 |
900/820 |
2000 |
2.65 |
15.70 |
0.5 |
3.150 |
3.26 |
0.987 |
900/820 |
Note:it can supply voltage regulating range of ±4×2.5% for high voltage of on-load regulation transformer according to the requirements. |
|
Omniseal transfrmer¡¡ UN-omniseal transformer |
|
Tecdhnical parameter,boundary dimension and installtion dimension
|
Rated capa
city (kVA) |
Voltage co
mbi
nat
ion (kV) |
Conn
ection type |
Impe
d
ance vo
%) |
Los
s(kW) |
No-lo
ad curr
ent (%) |
W
igh
(T) |
S9boun
dary
dime
nsion |
Gauge vertical/
horiz
ontal
(mm) |
No-lo
ad |
load |
mach
ine weig
ht |
oil
we
ight |
ove
rall we
ight |
omni
seal |
Un-
omni
seal |
10 |
11
10.5
10
6.3
6
0.4 |
T yno |
4 |
0.07 |
0.32 |
2.88 |
0.120 |
0.055 |
0.220 |
|
940
×690
×1000 |
400/
400 |
20 |
0.09 |
0.44 |
2.56 |
0.130 |
0.065 |
0.260 |
|
1065
×450
×1135 |
400/
400 |
30 |
0.10 |
0.60 |
1.60 |
0.220 |
0.095 |
0.390 |
1050×
570
×1100 |
1050
×570
×1185 |
400/
400 |
50 |
0.13 |
0.87 |
1.52 |
0.248 |
0.115 |
0.525 |
1080×
600
×1150 |
1080
×600
×1120 |
450/
400 |
63 |
0.15 |
1.04 |
1.44 |
0.350 |
0.120 |
0.585 |
1100×
635
×1150 |
1100
×635
×1300 |
450/
400 |
80 |
0.18 |
1.25 |
1.36 |
0.405 |
0.135 |
0.660 |
1150×
675
×1095 |
1150×
675
×1245 |
450/
400 |
100 |
0.20 |
1.50 |
1.24 |
0.470 |
0.145 |
0.750 |
1170×
715
×1220 |
1170×
715
×1370 |
450/
400 |
125 |
0.24 |
1.80 |
1.16 |
0.530 |
0.155 |
0.830 |
1230×
740
×1270 |
1230
×740
×1420 |
550/
400 |
160 |
0.28 |
2.20 |
1.04 |
0.620 |
0.175 |
0.960 |
1320×
800×
1290 |
1320
×800
1410 |
550/
550 |
200 |
0.34 |
2.60 |
0.96 |
0.690 |
0.195 |
1.090 |
1330×
770
×1360 |
1330
×770
×1510 |
550/550 |
250 |
0.40 |
3.05 |
0.88 |
0.835 |
0.225 |
1.280 |
1380×
770
×1380 |
1380×770
×1530 |
650/
550 |
315 |
0.48 |
3.65 |
0.80 |
0.980 |
0.240 |
1.470 |
1520×
870
×1460 |
1520
×870
×1610 |
650/
550 |
400 |
0.57 |
4.30 |
0.80 |
1.030 |
0.303 |
1.620 |
1550×
900
×1500 |
1550
×900
×1650 |
750/
550 |
500 |
0.68 |
5.15 |
0.72 |
1.370 |
0.305 |
2.040 |
1630×
970
×1580 |
1630
×970
×1730 |
750
/660 |
630 |
Y yno
&
Dynll |
4.5 |
0.81 |
6.20 |
0.64 |
1.530 |
0.450 |
2.330 |
1700×
970
×1650 |
1700
×970
×1850 |
750/
660 |
800 |
0.98 |
7.50 |
0.56 |
1.710 |
0.490 |
2.670 |
1750×
985
×1650 |
1750×
985×
1980 |
850/
660 |
1000 |
1.15 |
10.3 |
0.48 |
2.20 |
0.570 |
3.100 |
1840×
1040
×1770 |
1840×
1040
×1970 |
850
/820 |
1250 |
1.36 |
12.8 |
0.48 |
2.470 |
0.670 |
3.700 |
1930×
1100
×1810 |
1930×1
100×
2020 |
850/
820 |
1600 |
1.64 |
14.5 |
0.48 |
2.850 |
0.790 |
4.500 |
2100×
1180
×1930 |
2100×1180
×2150 |
900/
820 |
2000 |
2.10 |
17.1 |
0.40 |
3.750 |
0.980 |
5.440 |
2150×
1200
×1950 |
2150×
1200
×2170 |
900/
820 |
2500 |
2.0 |
23.2 |
0.32 |
3.720 |
1.180 |
5.900 |
2160×
1220
×1970 |
2160×1
220×
2190 |
1070/
1070 |
Note:1.it can supply voltage regulating range of ±5% or ±2×2.5%
high voltage of non-exciting regulation transformer according to the
requirements. 2.it can supply voltage regulating range of ±2×2.5%
or ±3×2.5% for high voltage of on-load regulation transformer according to
the requirements. |
|
|
|
|
|
|
|
|
|
|
|